50 © 2006 Directed Electronics—all rights reserved
3-9 2
nd
IGNITION/ACCESSORY OUTPUT: This will allow the PINK/WHITE to be used as a 2
nd
ignition or an acces-
sory. The default is 2
nd
ignition.
3-10 ACCESSORY STATE DURING WAIT-TO-START OFF/ON: This feature will allow the selection of the accessory
output to be ON or OFF during wait-to-start.
3-11 2nd STATUS OUTPUT NORMAL/REAR DEFOGGER LATCHED 10-MIN/PULSE: This feature will allow selection
of status output or a rear defogger mode that turns on ten seconds after the vehicle has started if the vehicle
interior temperature is below 55 degrees F. The defogger mode has two selections, latched or pulsed. Latched
mode will only stay on for 10 minutes.
3-12 ANTI-GRIND ON/OFF: With the anti-grind On (default) the ground-when-armed output will be active during
remote start operation. If accessories such as a voice module or window module are added to the unit, it may be
necessary to program this feature off.
3-13 DIESEL TIMER—WAIT-TO-START/15, 30, 45 SECONDS: Default is the “Wait-to-Start” input control
wire, or programmable to ignore the input control wire by a delay of 15, 30, or 45 seconds. This feature
can be also programmed with the Bitwriter® and with a delay from 1 to 90 seconds.
3-14 TIMER MODE—TIMED STARTS/TEMPERATURE STARTS: The system will start every 3-hours until can-
celed by the brake, hood, or neutral safety shut-down wires (a maximum of 6 times). The temperature start
mode will not start the vehicle unless the interior temperature of the vehicle is less than 0 degrees F. The tem-
perature start mode will exit after 18 hours.
3-15 RUN TIME (TIMER MODE)—12, 3, 6, 9 MINUTES: Selects the time in minutes that the system will
operate the engine until the system "times out". This is the maximum operation period and the system
may be shut down using a shutdown at any time. Using the Bitwriter®, the run time can be programmed for any
duration from 1-16 minutes.
nuisance prevention® circuitry
NPC requires that you change the way you test the system as NPC will bypass an input zone for 60 minutes. If
the system “sees” the same zone trigger three times AND the triggers are spaced less than an hour apart, the
system will bypass that input zone for 60 minutes. If that zone does not attempt to trigger the system during
the 60-minute bypass period, the zone’s monitoring will begin again at the end of the hour. If it does attempt
to trigger while bypassed, the 60-minute bypass starts over again.
Disarming and rearming the system does not reset NPC. The only way to reset NPC is for the 60 minutes to pass,
without a trigger, or for the ignition to be turned on. This allows the system to be repeatedly triggered, disarmed