48 © 2006 Directed Electronics—all rights reserved
pulse.
2-9 FACTORY ALARM DISARM WITH CHANNEL 2: In the default setting the factory alarm disarm output will
disarm the factory alarm system any time the button(s) controlling Channel Two is pressed.
2-10 FACTORY ALARM DISARM—WITH UNLOCK, BEFORE UNLOCK, REMOTE START ONLY: In the default setting the
factory alarm disarm output will disarm the factory alarm system any time the button(s) controlling Unlock is pressed.
The “Before Unlock” output to disarms the factory alarm before the unlock output activates and before remote start
is activated. The “Remote Start Only” output disarms the factory alarm only before the remote start is activated.
2-11 FACTORY ALARM DISARM PULSES—SINGLE, DOUBLE: Selectable for a single or double-pulse for the vehicle’s
factory alarm disarm input requirements.
2-12 CHANNEL 4 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED OUTPUT: This wire pro-
vides a (-) 200mA output whenever the transmitter button(s) controlling Channel 4 is pressed. This output can
be programmed to provide the following types of outputs (see also the Feature Menus section):
■ Validity: Output that will send a signal as long as the transmission is received.
■ Latched: Output that will send a signal when the Channel 4 button(s) is pressed and will continue until the
same button(s) is pressed again.
■ Latched, reset with ignition: Similar to the latched output, this type of output turns on the first time the
Channel 4 button(s) is pressed and turns off the next time the same button is pressed. This type of output
additionally stops and resets whenever the ignition is turned on and then off.
■ 30-second timed: Output that will send a continuous signal for 30 seconds.
Note: All auxilary channel timed outputs can be programmed using the Bitwriter® (1-90 seconds).
2-13 CHANNEL 4 LINKING (NONE)/ARM, DISARM, REMOTE START: When programming to validity or timed
output this can be programmed to activate when arming or disarming (or remote start) with the transmitter.
2-14 CHANNEL 5 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED OUTPUT: Channel Five
can be programmed for these output configurations. The unit is set to the default validity output. To change the
configuration, use the two-chirp setting to toggle through the different configurations. Refer to feature 2-10 for
additional detail.
2-15 CHANNEL 5 LINKING (NONE)/ARM, DISARM, REMOTE START: Refer to feature 2-13 for additional detail.
2-16 CHANNEL 6 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED OUTPUT: Channel Five
can be programmed for these output configurations. The unit is set to the default validity output. To change the
configuration, use the two-chirp setting to toggle through the different configurations. Refer to feature 2-10 for
additional detail.
2-17 CHANNEL 6 LINKING (NONE)/ARM, DISARM, REMOTE START: Refer to feature 2-13 for additional detail.