Directed Audio VSS-204TW Automobile Alarm User Manual


 
NOTE: When the shock sensor adjustment mode is exited, the bar
indicator will indicate continuously. For example if level 15 was being
set (bars 1 through 7 indicating continuously, and bar 8 flashing), upon
exiting adjustment mode bars 1 through 8 will indicate continuously.
Bar No.1 Bar No.10
Sensor level setting Shown at mid-point
2. Decrease Sensitivity—Press and release the
button to decrease shock sensor
sensitivity by one step. The siren will beep 1-time for each step decreased in adjustment
(1 vibrate if programmed). The shock sensor adjustment reaches minimum sensitivity
(sensor Off ) when the indicator bar is empty .
3. Testing Sensor—Use the heel of the palm of your hand to strike the door pillar of the car
after any increase or decrease in adjustment. The siren will chirp once if the impact was
great enough to generate a full trigger. Pre-warn level is set automatically. When
desired setting is reached, sensor adjustment mode can be exited.
EXIT SHOCK SENSOR ADJUSTMENT MODE:
The adjustment mode will be exited if:
No input from transmitter for 15-seconds.
No input from sensitivity testing for 15-seconds.
The ignition is turned On.
The Valet button is pressed.
The siren and LCD remote will emit 1 long beep and the LED will extinguish when shock
adjustment mode is exited.
RESET SHOCK SENSOR TO DEFAULT SETTING:
The shock sensor can be restored to a default setting of 10 to facilitate re-adjustment at any time
while in adjustment mode.
1. Simultaneously press the
and buttons.
2. The LCD remote will emit 3 quick beeps to indicate the sensor has been reset to level 10
(mid-range).
3. The system returns to shock sensor adjustment mode for further adjustment, if
required.
16
© 2006 Astroflex Electronics - All rights reserved