Directed Audio VSS-204TW Automobile Alarm User Manual


 
NOTE: The LCD transmitter will also have the
zone 2 icon and the alarm icon indicating.
4. The in vehicle LED will illuminate continuously for the duration of shock adjustment
mode.
NOTE: When the shock sensor adjustment mode is
entered, all other timers and operations are bypassed
until shock sensor adjustment mode is exited.
ADJUSTING THE SHOCK SENSOR SETTING
NOTE: When adjusting the shock sensor,
ensure that the vehicle’s doors are closed.
1. Increase Sensitivity—Press and release the button to increase shock sensor sensitivity
by one step. The LCD transmitter beeps 2-times for each step increased in adjustment
(and/or 1 vibrate if programmed). When the shock sensor adjustment reaches
maximum sensitivity when the indicator bar is filled completely to the right
.
There are 21 levels of shock sensor adjustment, during sensor adjustment these levels
are displayed on the indicator bar as listed below.
NOTE: When the arm and disarm are programmed
to a single button, then the AUX button is used
to increase the sensitivity setting of the sensor.
Sensor
Adjustment
Level
Bar Number and
Indication
0
no bars displayed
1
bar 1 flashes
2
bar 1 solid
3
bar 1 solid, bar 2 flashes
4
bar 1-2 solid
5
bar 1-2 solid, bar 3 flashes
6
bar 1-3 solid
7
bar 1-3 solid, bar 4 flashes
8
bar 1-4 solid
9
bar 1-4 solid, bar 5 flashes
10
bar 1-5 solid
11
bar 1-5 solid, bar 6 flashes
12
bar 1-6 solid
13
bar 1-6 solid, bar 7 flashes
14
bar 1-7 solid
15
bar 1-7 solid, bar 8 flashes
16
bar 1-8 solid
17
bar 1-8 solid, bar 9 flashes
18
bar 1-9 solid
19
bar 1-9 solid, bar 10 flashes
20
bar 1-10 solid
15 © 2006 Astroflex Electronics - All rights reserved