IDENTIFYING THE
CAUSE OF A
PROBLEM
UGR004/1200 Moducon Belt Conveyor
TROUBLESHOOTING 6-3
The Troubleshooting section covers problems directly related
to the operation and maintenance of the belt conveyor.
This section does not provide solutions to problems that origi-
nate with other equipment. Additional troubleshooting help
can be found in manuals supplied with the other equipment.
The following alarm conditions will stop the belt conveyor
automatically:
The load on the belt exceeds the rated torque applied
to the motor for more than 5 seconds.
The LED indicator light flashes and the motor stops.
The motor cable or connector is disconnected.
The LED indicator light turns on and the motor stops.
Motor speed exceeds 2800 rpm.
The LED indicator light turns on and the motor stops.
Voltage applied to the control is 30% or more below the
the voltage setting.
The LED indicator light turns on and the motor stops.
When an alarm occurs during operation, the belt conveyor
stops. The belt will not move and the alarm light will continue
to flash or stay lit until the error is corrected.