Conair UGR004/1200 Automobile Parts User Manual


 
UGR004/1200 Moducon Belt Conveyor
OPERATION 4-3
STOPPING THE
CONVEYOR
To stop the conveyor during operation:
Slide the control button to
the Standby position.
IMPORTANT: The Standby position is not a Power
OFF switch. When you want to stop the conveyor
motor for a long time, disconnect the conveyor from
the main power source.
To stop the conveyor for maintenance or repair:
Slide the control button to
the Standby position.
Disconnect the unit from the power source.
Remove the power plug from the electrical outlet. Follow
the lockout/tagout procedures developed in your facility to
ensure that power cannot be restored to the unit until the
maintenance or repair has been completed.
NOTE: Alarm conditions may stop the conveyor.
The conveyor will stop automatically under the following
alarm conditions:
The load on the belt exceeds the rated torque
applied to the motor for more than 5 seconds.
The LED indicator light flashes and the motor stops.
The motor cable or connector is disconnected.
The LED indicator light turns on and the motor stops.
The motor speed exceeds 2800 rpm.
The LED indicator light turns on and the motor stops.
Voltage applied to the control is 30% or more
below the the voltage setting.
The LED indicator light turns on and the motor stops.
2
1
1