UGR004/1200 Moducon Belt Conveyor
OPERATION 4-3
STOPPING THE
CONVEYOR
To stop the conveyor during operation:
Slide the control button to
the Standby position.
IMPORTANT: The Standby position is not a Power
OFF switch. When you want to stop the conveyor
motor for a long time, disconnect the conveyor from
the main power source.
To stop the conveyor for maintenance or repair:
Slide the control button to
the Standby position.
Disconnect the unit from the power source.
Remove the power plug from the electrical outlet. Follow
the lockout/tagout procedures developed in your facility to
ensure that power cannot be restored to the unit until the
maintenance or repair has been completed.
NOTE: Alarm conditions may stop the conveyor.
The conveyor will stop automatically under the following
alarm conditions:
● The load on the belt exceeds the rated torque
applied to the motor for more than 5 seconds.
The LED indicator light flashes and the motor stops.
● The motor cable or connector is disconnected.
The LED indicator light turns on and the motor stops.
● The motor speed exceeds 2800 rpm.
The LED indicator light turns on and the motor stops.
● Voltage applied to the control is 30% or more
below the the voltage setting.
The LED indicator light turns on and the motor stops.
2
1
1