INSTALLATION DIRECTIVE MAY 2006
22
V08 ENT M75
-
M11
-
M12
Battery recharging
This is accomplished through the power supply line of
the electric starter motor and connection to the +B of
the alternator. The electronic regulator of the alternator
that equips the engine allows an effective control over the
battery recharging operation.
If, due to installation requirements, the batteries need to be
positioned at a distance from the engine, we recommend
increasing the cross section of the power line conductors
and verifying recharging effectiveness by measuring voltage
across the battery poles.
For the best control of the battery recharge cabling the line
relating to the S terminal of the alternator directly to the
positive pole terminal of the battery (see figure 17).
Figure 17
Figure 16
Connect to positive
pole terminal of the
starter motor
B+
S
IG
L
05_073_V
B−
Connect to negative pole terminal
of the starter motor
Connect to positive
pole terminal of the
battery
Connect to positive
pole terminal of the
starter motor
B+
S
IG
L
05_075_V
B−
Connect to negative pole terminal
of the starter motor
IGS+B
L
05_074_V
Connect to positive pole
terminal of the battery