INSTALLATION DIRECTIVE
12
V08 ENT M75
-
M11
-
M12
MAY 2006
5. TECHNICAL DATA FOR INSTALLATION
V08 ENT
M75
V08 ENT
M11
V08 ENT
M12
Engine intake and ventilation air when underway
Static vacuum allowed downstream of the air filter
kPa
mmH
2
O
≤ 3.5
≤ 350
≤ 3.5
≤ 350
≤ 3.5
≤ 350
Engine air intake flow rate
m
3
/h
≥ 3050 ≥ - ≥ 4000
Engine room ventilation air flow rate (excluding engine air intake)
m
3
/h
≥ 7950 ≥ - ≥ 6600
Static vacuum allowed in the engine room
kPa
mmH
2
O
≤ 0.1
≤ 10
≤ 0.1
≤ 10
≤ 0.1
≤ 10
Temperature allowed in the engine room
°C
≤ 45 ≤ - ≤ 40
Maximum engine room temperature exceed outside temperature
°C
≤ 15 ≤ 15 ≤ 15
Exhaust gas outlet
Allowed static back pressure
kPa
mmH
2
O
≤ 10
≤ 1000
≤ 10
≤ 1000
≤ 10
≤ 1000
Temperature at maximum power (turbocharger inlet)
°C
510 ± 25 - 660 ± 25
Flow rate at maximum power
kg/h
3550 - 4800
Riser outer diameter
mm
inches
-
-
-
-
-
-
Dry exhaust outer diameter
mm
inches
105
4
105
4
105
4
Diameter of circumference of distance between 6 locking holes
mm
inches
127
5
127
5
127
5
Fuel supply
Low pressure pump delivery at maximum rpm
l/h
400 400 400
Fuel temperature to allow maximum power
°C
≤ 70 ≤ 70 ≤ 70
Inner diameter, intake pipe
mm
≥ 14 ≥ 14 ≥ 14
Inner diameter, return pipe
mm
≥ 8 ≥ 8 ≥ 8
Thread on prefilter fittings
M
14 x 1.5 14 x 1.5 14 x 1.5
Thread on engine fittings
inches
UIC
1/2 1/2 1/2
Allowed intake vacuum
kPa
mmH
2
O
≤ 50
≤ 5000
≤ 50
≤ 5000
≤ 50
≤ 5000
Allowed intake pressure
kPa
mmH
2
O
≤ 20
≤ 2000
≤ 20
≤ 2000
≤ 20
≤ 2000
Open sea water cooling line
Intake pipe outer diameter
mm
inches
101
4
101
4
101
4
Pump delivery at maximum rpm
l/h
61000 - 78000
Allowed intake vacuum
kPa
mmH
2
O
≤ 20
≤ 2000
≤ 20
≤ 2000
≤ 20
≤ 2000
Discharge pipeline outer diameter from air/water heat exchanger
mm
inches
51
2
51
2
51
2
Discharge pipeline diameter outer from water/water heat exchanger
mm
inches
89
3½
89
3½
89
3½