169
CURRENT IS APPLIED AT ALL TIMES THROUGH POWER FUSE TO TERMINAL 5 OF POWER MAIN RELAY AND ALSO THROUGH DOME
FUSE TO TERMINAL 12 OF MOON ROOF CONTROL RELAY.
WITH THE IGNITION SW TURNED ON, THE CURRENT FLOWS FROM TERMINAL 1 OF POWER MAIN RELAY → TERMINAL 2 → TO
GROUND THROUGH GAUGE FUSE. AS A RESULT, POWER MAIN RELAY IS ACTIVATED AND THE CURRENT TO TERMINAL 5 OF
POWER MAIN RELAY FLOWS FROM TERMINAL 3 OF RELAY TO TERMINAL 6 OF MOON ROOF CONTROL RELAY.
1. SLIDE OPEN OPERATION
WHEN THE IGNITION SW IS TURNED ON AND THE MOON ROOF CONTROL SW IS PUSHED TO THE OPEN POSITION, A SIGNAL IS
INPUT FROM TERMINAL 3 OF MOON ROOF CONTROL SW TO TERMINAL 1 OF MOON ROOF CONTROL RELAY. MOON ROOF LIMIT SW
NO. 2 ON AT THIS TIME.
WHEN THIS OCCURS, THE RELAY IS ACTIVATED AND THE CURRENT TO TERMINAL 6 OF MOON ROOF CONTROL RELAY FLOWS
FROM TERMINAL 5 → TERMINAL 1 OF MOON ROOF MOTOR → TERMINAL 3 → TERMINAL 4 OF MOON ROOF CONTROL RELAY →
TERMINAL 11 → TO GROUND AND ROTATES THE MOTOR TO OPEN THE MOON ROOF WHILE THE SW IS BEING PUSHED TO OPEN
POSITION.
2. SLIDE CLOSE OPERATION
WITH THE IGNITION SW TURNED ON, THE MOON ROOF COMPLETELY OPEN AND MOON ROOF LIMIT SW NO. 1 AND NO. 2 BOTH ON,
WHEN THE MOON ROOF CONTROL SW IS PUSHED TO THE CLOSE POSITION A SIGNAL IS INPUT FROM TERMINAL 6 OF MOON
ROOF CONTROL SW TO TERMINAL 2 OF MOON ROOF CONTROL RELAY.
WHEN THIS OCCURS, THE RELAY IS ACTIVATED AND THE CURRENT TO TERMINAL 6 OF MOON ROOF CONTROL RELAY FLOWS
FROM TERMINAL 4 → TERMINAL 3 OF MOON ROOF MOTOR → TERMINAL 1 → TERMINAL 5 OF MOON ROOF CONTROL RELAY →
TERMINAL 11 → TO GROUND AND ROTATES THE MOTOR TO CLOSE THE MOON ROOF WHILE THE SW IS BEING PUSHED TO CLOSE
POSITION.
MOON ROOF LIMIT SW NO. 1 TURNS OFF (LIMIT SW NO. 2 IS ON) AND A 100 MM BEFORE FULLY CLOSE POSITION, SIGNAL IS INPUT
FROM TERMINAL 1 OF LIMIT SW NO. 1 TO TERMINAL 8 OF MOON ROOF CONTROL RELAY. THIS SIGNAL ACTIVATES THE RELAY AND
STOPS CONTINUITY FROM TERMINAL 6 OF MOON ROOF CONTROL RELAY TO TERMINAL 11. AS A RESULT, THE MOON ROOF
STOPS AT THIS POSITION.
TO CLOSE THE MOON ROOF COMPLETELY, PUSHING THE MOON ROOF CONTROL SW AGAIN TO THE CLOSE SIDE CAUSES A
SIGNAL TO BE INPUT AGAIN TO TERMINAL 2 OF MOON ROOF CONTROL RELAY. THIS ACTIVATES THE RELAY AND THE MOON ROOF
WILL CLOSE AS LONG AS THE MOON ROOF CONTROL SW IS BEING PUSHED, ALLOWING THE MOON ROOF TO FULLY CLOSE.
3. TILT UP OPERATION
WHEN THE MOON ROOF CONTROL SW IS PUSHED TO TILT UP POSITION, WITH THE IGNITION SW TURNED ON AND THE MOON
ROOF COMPLETELY CLOSED (MOON ROOF LIMIT SW NO. 2 IS OFF), A SIGNAL IS INPUT FROM TERMINAL 5 OF MOON ROOF
CONTROL SW TO TERMINAL 3 OF MOON ROOF CONTROL RELAY. AS A RESULT, THE RELAY IS ACTIVATED AND THE CURRENT TO
TERMINAL 6 OF RELAY FLOWS FROM TERMINAL 4 OF RELAY → TERMINAL 3 OF MOON ROOF MOTOR → TERMINAL 1 → TERMINAL
5 OF RELAY → TERMINAL 11 TO GROUND AND ROTATES THE MOTOR SO THAT TILT UP OPERATION OCCURS AS LONG AS THE
MOON ROOF CONTROL SW IS PUSHED ON THE TILT UP SIDE.
4. TILT DOWN OPERATION
WHEN THE MOON ROOF CONTROL SW IS PUSHED TO TILT DOWN POSITION, WITH THE IGNITION SW TURNED ON AND THE MOON
ROOF TILTED UP (NO. 1 AND NO. 2 MOON ROOF LIMIT SWITCHES ARE BOTH OFF), A SIGNAL IS INPUT FROM TERMINAL 2 OF MOON
ROOF CONTROL SW TO TERMINAL 7 OF MOON ROOF CONTROL RELAY.
AS A RESULT, THE RELAY IS ACTIVATED AND THE CURRENT TO TERMINAL 6 OF RELAY FLOWS FROM TERMINAL 5 OF RELAY →
TERMINAL 1 OF MOON ROOF MOTOR → TERMINAL 3 → TERMINAL 4 OF RELAY → TERMINAL 11 → TO GROUND AND ROTATES THE
MOTOR SO THAT TILT DOWN OPERATION OCCURS AS LONG AS THE MOON ROOF CONTROL SW IS PUSHED ON THE TILT DOWN
SIDE. (DURING TILT DOWN, LIMIT SW NO. 1 IS CHANGED OFF TO ON.)
5. TILT UP REMINDER SYSTEM
WHEN THE IGNITION SW IS TURNED FROM ON TO ACC OR OFF WITH THE MOON ROOF STILL TILTED UP THE CURRENT DOES NOT
FLOW TO TERMINAL 6 OF MOON ROOF CONTROL RELAY.
THIS IS RECEIVED BY THE RELAY AS A SIGNAL THAT THE IGNITION SW IS TURNED OFF. AT THIS TIME, MOON ROOF LIMIT SW NO.1
AND NO. 2 ARE OFF, SO SIGNALS ARE INPUT TO TERMINALS 8 AND 9 OF MOON ROOF CONTROL RELAY THAT THE MOON ROOF IS
IN THE TILT OPERATION POSITION. WHEN THESE SIGNALS ARE INPUT TO THE MOON ROOF CONTROL RELAY, THE TIMER BUILT
INTO THE RELAY OPERATES.
THUS THE CURRENT TO TERMINAL 12 OF MOON ROOF CONTROL RELAY FLOWS THROUGH BUZZER OF MOON ROOF CONTROL
RELAY AND TERMINAL 11 OF MOON ROOF CONTROL RELAY TO GROUND AND THE BUZZER SOUNDS ABOUT 8 TIMES TO NOTIFY
THAT THE MOON ROOF IS STILL IN THE TILT UP CONDITION.
SYSTEM OUTLINE