Sierra 220 Automobile Parts User Manual


 
Series 220/221 Instruction Manual Chapter 3 Operation
Calibration Menu
Password
ENTER
Use
keys to access menus
Calibration
Menu
Meter Size
or Pipe ID
ENTER
Run Mode
Meter Factor
xxxx
Vortex Coef Ck
xx
Low Flow Cutoff
xx
Serial Number
xxxxxxxxx
Series 220 - meter size
Series 221 - pipe internal diameter (inches)
Meter calibration constant
Series 220 - pulses/ft
3
Series 221 - pulses/ft
Adaptive filter setting
Low Flow Cutoff
setting displayed
in volumetric flow
units (view only)
Process Temp(°F)
xxx
Used to correct Meter Factor for thermal
expansion of meter body for Series 220
Density
xxx
Units are lb/ft
3
Ref Density
xxx
Units are lb/ft
3
. Used for calculation of
standard cubic meters, standard cubic feet,
and normal cubic meters.
Viscosity
xxx
Units are centipoise (Cp)
< Vol (xxx/xxx) >
xxx
< Mass (xxx/xxx)
xxx
Low Flow Cutoff
setting displayed
in mass flow
units (view only)
The Calibration Menu contains the calibration coefficients for the flow meter. These
values should by changed only by properly trained personnel. The Vortex Coef Ck and
Low Flow Cutoff are set at the factory. Consult the factory for help with these settings if
the meter is showing erratic flow rate. The units of measurement used in the Calibration
Menu are preset and are as follows: Density = lbm/ft
3
, Reference Density = lbm/ft
3
,
Viscosity = centipoise.
IM-22 3-9