Outback Power Systems FX 2532MT Automobile Battery Charger User Manual


 
Installation & Programming Manual FX & VFX Series Inverter/Charger System Copyright 2003 OutBack Power Systems, Inc.
900-0027-1 19009 62
nd
Ave NE, Arlington WA 98223 USA
Page 38 Rev 7.2 08/26/05 Tel 360 435 6030 Fax 360 435 6019
MATE – SYSTEM CONTROLLER AND DISPLAY
Inverter Control
The OutBack MATE includes an INV “hot” key to allow direct control of the inverter from anywhere in the menu system. The INV key is
located on the right side of the MATE LCD display. Pressing the INV key takes you to the INVERTER CONTROL menu shown below.
A green LED indicator is located above the INV key which flashes when the inverter is either in the search or power save modes and is
on continuously when full AC output voltage is available from the inverter. When the inverter is turned off the green LED will not be
illuminated.
INVERTER CONTROL
currently: ON
OFF SRCH ON OK
Pressing the INV key once brings up the INVERTER CONTROL screen. To turn the inverter
ON, press the key located below the word ON. Selecting SRCH will cause the inverter to begin
operating in the search mode as long as the AC load connected is smaller than allowed by the
programming of the search function. Selecting OFF turns off the inverters AC output signal.
Select OK to return to the point in the menu system from where you entered the INVERTER
CONTROL screen.
INV
INV