Furuno GP-90-DUAL GPS Receiver User Manual


 
10. INSTALLATION
10-10
In great circle calculation, BWC and WNC are output but BWR and WNR are not.
In rhumb line navigation, BWR and WNR are output but BWC and WNC are not.
The total data output are shown by percentage on the third line.
For best results the total output should be less than 90%; lengthen the Tx
interval of less important data to make the total output less than 90%.
DATA 3 output setting
The DATA 3 can output NMEA 0183 (V1.5/V2.0) /IEC 61162-1 data or log pulse
depending on jumper wire setting on the NAV board. For NMEA 0183
(V1.5/V2.0) /IEC 61162-1, the same signal of DATA 1 is output from DATA 3.
Selection of NMEA0183 or log pulse
Output data
NAV board
NMEA 0183 (V1.5/
V2.0)/IEC 61162-1
Log pulse
JP4 (2 pcs.) ON OFF
JP5 (3 pcs.) OFF ON
Rate of log pulse output
500 mA Max.
50 VDC
Procedure for setting of log pulse rate
1) Press [ESC MENU], [9] and [3].
2) Press
to select DATA 3. Log Pulse.
3) Press
or to select log pulse for external equipment; 200ppm or
400ppm.
4) Press the [CU/NU ENT] key.
5) Press the [MENU ESC] key.