Furuno FR-2105 Radar Detector User Manual


 
-1.47-
The picture setup options assignable to any of the function keys are shown in the table below:
LABEL DESCRIPTION LABEL DESCRIPTION
BUOY Optimum setting for detecting
navigation buoys, small vessels
and other small surface objects
SHIP Optimum setting for detecting
vessels
SHORT Optimum setting for short range
detection using a range scale of
3 nm or less on calm seas
LONG Optimum setting for long range
detection using a range scale of
6 nm or larger
CRUISING For cruising using a range scale
of 1.5 nm or larger
HARBOR Optimum setting for short range
navigation in a harbor area
using a range scale of 1.5 nm or
less
COAST For coastal navigation using a
range of 12 nm or less
SEA Transoceanic voyage using a
range scale of 12 nm or larger
ROUGH
SEA
Optimum setting for rough
weather or heavy rain
RIVER Optimum setting for navigation
on a river
Each picture setup option defines a combination of several radar settings for achieving
optimum setup for a particular navigating situation. Those involved are interference rejector,
echo stretch, echo average, automatic anti-clutter, pulselength and noise rejector settings.
Adjusting these features on a function key menu changes the original function key settings.
To restore the original settings for a particular function key, it is necessary to display the
relevant function key menu and select appropriate menu options.
Note: Function key presetting requires a good knowledge of optimum radar settings. If you
want to change the original function key settings, consult your nearest FURUNO
representative or dealer.
1.33.2 Specific operation
Most often used controls are placed on the center panel while less often used controls are
provided in the menu. To avoid opening the menus to set up the radar for a particular
situation, function keys #1, #2, #3 and #4 may be assigned a combination of the following
settings at the time of installation.
- Target trails (See paragraph 1.25.)
- Echo stretch 1,2 or 3 (See paragraph 1.22.)
- Pulselength 1 or 2 (See paragraph 1.11.)
- Echo averaging 1, 2 or 3 (See paragraph 1 .23.)
- Echo color (See paragraph 1.32.)
- Panel illumination
- Marks brilliance
- Noise rejection
Provided that the function key is assigned the specific operation feature, press the key to instantly
set the radar for the preset purpose. The corresponding label will be displayed at the left margin of
the screen. If you re-press the function key, the radar returns to the previous settings.