2. OPERATION MESSAGES ON SETTING AND DISPLAY UNIT
2.1 Operation Errors
I - 49
Error No. Error message Details
E50
E51
E52
E53
E54
E55
E56
FILE ERR
FILE OPEN ERR
FILE CLOSE ERR
FILE SEEK ERR
FILE READ ERR
FILE DELETE
ERR
FILE INSERT ERR
×
• If one of these errors occurs‚ the editing or input/output
operations cannot be continued. Contact the Service Center.
As for E50‚ a classification No. will display at the end of the
message. Inform the service center of this No. as well.
E60
IOP ERR
×
A classification number is displayed after the message for E60.
Refer to the section shown in parentheses‚ and remedy the
problem.
E60 lOP ERROR – 2 (Port already being used)
E60 lOP ERROR – 4 (E09 TIME OUT)
E60 lOP ERROR – 5 (E08 PHYSICAL ERR)
E60 lOP ERROR – 7 (E07 RESET END)
E60 lOP ERROR – 10 (E04 DEV. NOT READY)
E60 lOP ERROR – 15 (E17 PARITY H ERR)
E60 lOP ERROR – 16 (E18 PARITY V ERR)
E60 lOP ERROR – 17 (E20 OVER RUN ERR)
E60 lOP ERROR – 18 (E22 CODE CHANGE ERR)
E60 IOP ERROR – 20 (framing and H/W errors)
• Setting for the bit length is incorrect. (Baud rate, stop bit, and
character length)
Check the setting of the I/O device system and its parameters
and set it again.
• Check the situations of the connected devices (cable wiring and
noise measures).
• Data was input/output or the tape search was executed during
the host link.
Set 0 in #8109 HOST LINK, and then set 1 again before
performing the cycle start. (IOP error -2)
• The host link parameter was turned ON during connecting to the
Anshin-net. Turn the Anshin-net valid OFF. (IOP error -2)
• When #10812 Anshin-net/ Machine builders network system
valid is set to 1, the modem connection port of the Anshin-net or
machine builders network system is occupied.
• When connecting the GX Developer (when the bit selection
parameter #6451 bit5 is set to 1), the port 2 of the RS232C
communication port is always used.
Disconnect Gx Developer from the RS232C communication port
as it has only 1ch (2 ports) available. (Set #6451 bit5 to "0") (IOP
error -2)