A SERVICE OF

logo

5. BASE SPECIFICATIONS PARAMETERS
II - 57
# Items Details Setting range (unit)
aux07
(bit4)
Synchronous
tap hole bottom
in-position
check
0: Disable the synchronous tap hole bottom
in-position check.
1: Enable the synchronous tap hole bottom
in-position check.
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0/1
aux07
(bit5)
Synchronous
tap R-point
in-position
check 2
0: Disable synchronous tape R-point in-position
check.
1: Enable synchronous tape R-point in-position
check.
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0/1
aux07
(bit6)
Cancel
synchronous
tap (,S) return
0: Retains a spindle rotation speed (, S) when
performing synchronous tap return.
1: Cancels a spindle rotation speed (, S) by return
with G80.
0/1
aux07
(bit7)
Synchronous
tap method
Specify a synchronous tap method.
0: Synchronous tap (multi-step acceleration and
deceleration and rapid return)
1: Conventional type synchronous tap
0/1
1224 aux08
(bit0)
Sampling data
output
Set the validity of the sampling data output.
0: Sampling output invalid
1: Sampling output valid
0/1
1225 aux09
(bit0)
Not used.
aux09
(bit7)
Enable/disable
spindle
rotation speed
clamp
Specify whether to enable spindle rotation speed
clamp by the spindle rotation speed clamp command
(G92S, Q) instead of the spindle rotation speed
command (R108) specified by the user ladder.
0: Enable
1: Disable
0/1