6. AXIS SPECIFICATIONS PARAMETERS
6.1 Axis Specifications Parameters
II - 82
6. AXIS SPECIFICATIONS PARAMETERS
6.1 Axis Specifications Parameters
After setting up the parameter (PR) listed in the table, turn OFF the NC power. To validate the parameter,
turn ON the power again.
(SETUP PARAM 2. 1/8)
# Items Details Setting range (unit)
2001 rapid Rapid traverse
rate
Set up the rapid traverse feedrate for each axis.
The maximum value to be set differs with
mechanical systems.
1 to 999999 (mm/min)
2002 clamp Cutting feedrate
for clamp
function
Define the maximum cutting feedrate for each axis.
Even if the feedrate in G01 exceeds this value‚ the
clamp will be applied at this feedrate.
1 to 999999 (mm/min)
2003
(PR)
smgst Acceleration and
deceleration
modes
Specify acceleration and deceleration control
modes.
OT3
FEDCBA98765432 10
OT2 OT1 C3 C1 LC R3 R1 LR
Note: Set 0 in null bits. (Bit2 and bit6 when the
acceleration/deceleration by software is selected
are excluded.)
(To be continued to the next page)
Rapid traverse feed acceleration and
deceleration types
LR Linear acceleration/
deceleration
R1 Primary delay
R3 Exponential acceleration
and linear deceleration
bit0 to 3 ON Acceleration/
deceleration by software
Cutting feed acceleration and deceleration types
LC Linear acceleration/
deceleration
C1 Primary delay
C3 Exponential acceleration
and linear deceleration
bit4 to 7 ON Acceleration/
deceleration by software
Specify the modes in