![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/da/fda917fd-399b-406b-8a2c-48d9566ebb3e/fda917fd-399b-406b-8a2c-48d9566ebb3e-bgd2.png)
7. Vector Charts
7-46
7.7.6 How to load an RENC-generated permit CD ROM or floppy disk
An RENC can deliver permits in a CD ROM or a floppy disk. When you receive new permits from an RENC, you
have to load them into the chart radar. A permit is a key that is used to decrypt the chart you want to use in the chart
radar. To load permits, do the following:
1. Choose Chart Permits from the Chart menu.
.
2. Click the Load File button.
3. Choose correct drive from the Look in list box.
Permits are available in two formats.
• PERMIT.TXT that contain permits and their editions and subscription types. This is the preferred format.
• *.PMT, received from an RENC, contain permits, but no edition or subscription information. Note that the
*.PMT format is used by the system for backup of permits. As a backup it contain also subscription type and
edition.
• Choose suitable permit file and click the Open button to load permits.
The Chart Permits window displays permits that are loaded into the chart radar.
.