10.1 Typical Start Current Requirements
300%
350%
400%
450%
Agitator
Atomiser
Bottle Washer
Centrifuge
Chipper
Compressor - Recip (loaded)
Compressor - Recip (unloaded)
Compressor - Screw (loaded)
Compressor - Screw (unloaded)
Conveyor - Belt
Conveyor - Roller
Conveyor - Screw
Crusher - Cone
Crusher - Jaw
Crusher - Rotary
Crusher - Vertical Impact
Debarker
Dryer
Dust Collector
Edger
Fan - Axial (Damped)
Fan - Axial (Un-damped)
Fan - Centrifugal (Damped)
Fan - Centrifugal (Un-damped)
Fan - High Pressure
Grinder
Hydraulic Power Pack
Mill
Mill - Ball
Mill - Hammer
Mill - Roller
Mixer
Palletiser
Planer
Press
Pump - Bore
Pump - Centrifugal
Pump - Positive Displacement
Pump - Slurry
Re-pulper
Rotary Table
Sander
Saw - Bandsaw
Saw - Circular
Separator
Shredder
Slicer
Tumbler
The above table is intended as a guide only. Individual machine
and motor characteristics will determine the actual start current
requirements.
10.2 AC53a Utilisation Codes
AC53a Utilisation Category Format
78 A: AC-53a 3.5-15 : 50-10
S
t
a
r
t
e
r
C
u
r
r
e
n
t
R
a
t
i
n
g
(Amps)
Start Current (multiple of FLC)
Start Time (seconds)
On-load Duty Cycle (%)
Starts Per Hour
Starter Current Rating: The Full Load Current rating of soft
starter given the parameters detailed in the remaining sections
of the utilisation code.
Start Current: The maximum available start current given the
parameters detailed in the remaining sections of the utilisation
code.
Start Time: The maximum available start time given the
parameters detailed in the remaining sections of the utilisation
code.
On-load Duty Cycle: The maximum permissible percentage of
each operating cycle that the soft starter can operate given the
parameters detailed in the remaining sections of the utilisation
code.
Starts Per Hour: The maximum available number of starts per
hour given the parameters detailed in the remaining sections of
the utilisation code.
10.3 AC53b Utilisation Codes
AC53b Utilisation Category Format
90 A: AC-53b 3.5-15 : 345
S
t
a
r
t
e
r
C
u
r
r
e
n
t
R
a
t
i
n
g
(Amps)
Start Current (multiple of FLC)
Start Time (seconds)
Off Time (seconds)
Starter Current Rating: The Full Load Current rating of soft
starter given the parameters detailed in the remaining sections
of the utilisation code.
Start Current: The maximum available start current given the
parameters detailed in the remaining sections of the utilisation
code.
Start Time: The maximum available start time given the
parameters detailed in the remaining sections of the utilisation
code.
Off Time: The minimum allowable time between end of one start
and the beginning of the next start given the parameters detailed
in the remaining sections of the utilisation code.