North Star 25 kW Radar Detector User Manual


 
You can connect the radar processor to either the Northstar 6100i OR to the Northstar 8000i, but not
to both simultaneously.
25 kW radar processor interface connectors
Connector name Connector function Connects to...
Network Ethernet communications for
the 8000i
8000i network, using the 8000i
network cable (NS00481X)
Power (+Ve and -Ve) Power input Ship's power 24 V DC ONLY (using
the power cable)
NMEA / Comms Data communications (for the
6000i and 6100i systems
only)
Remote power control, relay
and ignition (for the 6000i,
6100i, and 8000i)
NMEA communications for
compass (for the 8000i only).
6000i or 6100i display unit, using
radar communications cable
(NS003107/NS003108)
6000i, 6100i, or 8000i remote
power signals, relay or ignition;
cable not supplied
8000i NMEA compliant compass;
cable not supplied
Scanner Scanner communications Scanner, using the
interconnection cable (NS003105
or NS003106)
Chassis Earth Grounding point Vessel's Ground using ground
wire
12.4 Run the interconnection cable (NS003105/NS003106) to the radar
processor
Run the interconnection cable (NS003105/NS003106) from the scanner unit to the radar processor.
Push the round connector (A) of the interconnection cable into the scanner connection on the radar
processor and tighten the locking nut.
Northstar 25 kW Radar Installation Manual
27