Chapter 6 Automotive Diagnostic Command Set API for C
Automotive Diagnostic Command Set User Manual 6-118 ni.com
ndOBDRequestCurrentPowertrainDiagnosticData
Purpose
Executes the OBD Request Current Powertrain Diagnostic Data service. Reads an ECU data
record.
Format
long ndOBDRequestCurrentPowertrainDiagnosticData(
TD1 *diagRef,
unsigned char PID,
unsigned char dataOut[],
long *len,
LVBoolean *success);
Input
diagRef
Specifies the diagnostic session handle, obtained from ndOpenDiagnostic and passed
to subsequent diagnostic functions. Normally, it is not necessary to manually manipulate
the elements of this struct.
PID
Defines the parameter identifier of the data to be read. The SAE J1979 standard defines
the values.
Output
dataOut
Returns the ECU data record. If you know the record data description, use
ndConvertToPhys to interpret this record. You can obtain the description from the
SAE J1979 standard.
len
On input, len must contain the dataOut array length. On return, it contains the number
of valid data bytes in the
dataOut array.
success
Indicates successful receipt of a positive response message for this diagnostic service.