e. Reassemble the oat switch. Replace the rubber boot and the oat switch in their
correct positions. Reconnect the vent tube.
f. Replace the right-side panel in its correct position.
9) Remove the insulation panel by removing the thumbscrews, then pour the cleaning
solution into the water tank.
10) Move the service switch to the "WASH" position.
11) Replace the insulation panel and the front panel in their correct positions.
1) Turn on the power supply to start the washing process.
13) Turn off the power supply after 30 minutes. Remove the front panel.
14) Move the service switch to the "DRAIN" position.
15) Replace the front panel and turn on the power supply for  minutes.
16) Turn off the power supply and remove the front panel.
17) Move the control switch to the "ICE" position.
18) Replace the front panel in its correct position.
19) Turn on the power supply to ll the water tank with water.
0) Turn off the power supply after 3 minutes.
1) Remove the front panel.
) Move the control switch to the "SERVICE" position, then move the service switch to the
"WASH" position.
3) Replace the front panel in its correct position.
4) Turn on the power supply to rinse off the cleaning solution.
5) Turn off the power supply after 5 minutes.
6) Remove the front panel.
7) Move the service switch to the "DRAIN" position.
8) Replace the front panel and turn on the power supply for  minutes.
9) Turn off the power supply. Remove the front panel.
30) Repeat steps 17 through 9 three more times to rinse thoroughly.
Note: If you do not sanitize the icemaker, go to step 13 in ". Sanitizing Procedure."