Furuno CI-35H GPS Receiver User Manual


 
4-10
2. RANGE SET MENU
RANGE
2.0kt
5.0
NM
100m
2 Distance range
For course plot
display
4 Color gradation range
For echo level display
in color mode
1 Speed range
For speed vector
graph
3 Depth range
For echo level
display
1. To change one of the above ranges, call the RANGE SET menu by pressing the
RANGE
key.
*RANGE SET*
KNOB ITEM
KNOB SETUP
END : RANGE
SPEED RANGE
: 10.0 kt
DIST RANGE
: 1.0 NM
ECHO DEPTH
: 150 m
ECHO SHIFT
: 1
Knob
Knob
(Note 1)
1Max. speed range
of tide/tide
differential vector
display
2Distance from center
(ship’s position) to
outermost ring (for
course plot display)
1.0 to 20.0 kt in
0.1 kt steps
0.5 to 5.0 nm in
0.5 nm steps
3Max. depth range for
“echo level” display
50 to 700 meters in
50 meter steps
4Color gradation factor
for “echo level” display
( * )
(1 to 36)
(Note 1) Changes the threshold levels for coloring echoes
with different strengths. (The higher the value, the
lower the thresholds, and vice versa.)
A gradation factor of 1 to 7 is recommended. The
higher (lower) the value, the greater the amount of
red (blue) in echoes.
Notice that the threshold shift dose not change the
receiver gain nor performance of the equipment,
although it changes echo color.
2. When desired range is set, press the
RANGE
key again.