CM6200 Install Guide
Starter System
www.firstechonline.com | www.compustar.com
Common Procedures CM6200
Jumper Settings
Caution: Jumper settings affect the polarity and use of certain outputs. If these jumpers are used incorrectly,
damage to the vehicle and /or control module may occur.
Jumper 1 (Door Trigger Polarity)
Determines the polarity of the door trigger input wire (red/white). In the default position the door trigger regis-
ters negative (-) triggers. To change to a positive (+) trigger, move the jumper.
Jumper 2 (Glow Plug or Key Sense Polarity)
Determines the polarity of the glow plug or key sense input wire (brown/white). In the default position it moni-
tors a positive (+) glow plug input. To change to a negative (-) input move the jumper. To change from the glow
plug to the key sense setting, you must change Option 4-09.
Jumper 3 (Parking Light to Trunk Output)
Determines the output type (not polarity) of the green/white wire on connector one (CN1). In the default posi-
tion it provides a positive (+) parking light output. To change to a positive (+) trunk output move the jumper. A
negative (-) parking light output is found on connector three (CN3) and a negative (-) trunk output is found on
connector four (CN4).
Setting Auxiliary Outputs on Connector 2 - You Must Have the OP500 Option Programmer
To set auxiliary outputs on the control module you must change Programmable Output Connector wires (POCs).
You must choose two odd pin wires on the black 18 pin connector that you are not using. For example we will
use POC 8 and 9.
STEP 1: Plug in OP500 and use the Right or Left Arrow Button to scroll through the menu to POC 8 and POC 9 on LCD Line 1.
STEP 2: Use the Up or Down Arrow Button to change the lower number on LCD Line 2 to 10 – Auxiliary 1 or 11- Auxiliary 2.
STEP 3: Scroll up the menu to Option 4-01 and 4-02 and set the options. Please see the Option Table for details.
STEP 4: The Pro control modules have a secure auxiliary option 4-05. This requires you to tap button 4 before you tap button 2 for
Aux 1 or button 3 for Aux 2. On 1-Way remotes you must hold the Trunk and Key/Start buttons for 2.5 seconds then tap the Trunk
button for Aux 1 or the Key/Start button for Aux 2.
STEP 5: If you need to change the time settings of the outputs go to AU1 or AU2 on the OP500. LCD Line 2 is the timed output.
STEP 6: Hold the “W” Write button for 3 seconds to set all the options.
Tach Sensing
The default engine sensing mode is tach. In cold weather climates we recommend using an injector wire verses
a coil wire for tachometer sense. There are new features that adjust tach reading methods on option 2-01. IM-
PORTANT: The remotes must be coded prior to setting up tach sensing. Firstech recommends using a digital
multimeter to test for tach.