Copyright 2009 Firstech, LLC.
Page 23
CM6200 Install Guide
Starter System
www.firstechonline.com | www.compustar.com
2-01 Tach Sensing Method – This option will adjust the method at which tach is read by the module. At de
fault this option will minimize overcrank during remote start.
2-02 Turbo Mode – This option will adjust the run time after Turbo mode has been engaged. The e-brake and
door trigger inputs must be connected and the option must be turned on through the remote for turbo
timer to engage.
2-03 Diesel Timer – Use this option if you can’t nd the glow plug wire. You can use setting 2 for a default
wait to start of 10 seconds, otherwise, you can adjust the time with your OP500 Programmer.
2-04 Trigger Start – This option changes the number of times required for a negative (-) start input on the
pink wire of connector 2.
2-05 Cold or Hot Start – This option turns on the cold/hot starting features. This option works in conjunction
with 2-6, 2-8 and 2-9. The thermister must also be connected the brain.
2-06 Timer Start or Interval Between Cold Start - This option dictates the time interval when the control mod
ule will either remote start or check the temperature and remote start.
Default 1: Will start every 3 hours until the vehicle is remote started or started by key and run for 4 min
utes.
Option 2: Will start every 1.5 hours until the vehicle is remote started or started by key and run for 4
minutes.
Option 3: Will start at the time specied on the 2 way remote once within 24 hours and run based on
Option 2-07.
Option 4: Will start once every 24 hours if the temperature falls below Option settings 2-08 or above
Option settings 2-09.
For example, if you want your car to start and run 25 minutes when the temperature falls below 32°F,
you need to set up the following options:
1) Option 2-05 (Cold Start) turned on,
2) Option 2-06-IV (24 hr. repeat) turned on,
3) Option 2-07-II (25 min run-time) turned on,
4) Option 2-08-IV (Temp 32°F) turned on,
*Set the reservation time at 7 am (see User’s guide)
**Turn on Timer Mode of the 2 way LCD remotes (see User’s Guide)
2-07 Remote Start Runtime - This option give you four different settings for the remote start run time. This
available options are 15, 25,45, and 3 minutes.
2-08 Temperature of Cold Starting – Works in conjunction with Options 2-05 and 2-06. See the option table
for available temperatures.