Audiovox AS9233ST Automobile Alarm User Manual


 
128-8605
3 of 20
3
To exit program mode, turn ignition off, or press and release valet switch.
RF Programmable Features Bank 3 Is Remote Start Selectable Features:
Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps
1st Defrost Output NA
2nd RF Start Chirp Off On On & Carfinder
3rd Run Time 5 Mins 10 Mins 15 Mins 20 Mins 45 Mins 60 Mins
4th Parking Lights On Steady Flashing
5th Input Check Voltage Tach DBI Tach Hybrid
6th Voltage Level >0.5V B4 Start < 0.5V B4 Start
7th Ign. 2 Select Off During Crank On During Crank Same As Accy.
8th Ign. 3 Select NA
9th Diagnostics Off On
10th Crank Time 0.8 Sec 1.0 Sec 1.5 Sec 2.0 Sec
11th Gas/Diesel Gas Diesel 10 Diesel 15 Diesel 20
12th Transponder O/P While R/S On During Start Until Ign. Off
13th Temp Start N A
14th Crank Averaging Averaging Preset Time
Note: When averaging, the engine must be started 4 times with the key to be effective.
15th R/S Shock Shunt Until Clear Shunt R/S Cycle Shunt From Tx
16th Turbo Select NA
17th Black/Blue (Aux O/P) Single Pulse As Feat #1 Bank 2
18th 1 or 2 Pulse to Start 2 Pulse 1 Pulse
When using the RF programmer, enter the program mode as follows:
Turn the ignition on.
Press and release valet switch 3 times.
Turn ignition off then on.
Press and hold valet switch for 5 seconds.
The siren chirps 2 times indicating access to RF feature program mode.
When using the RF programmer, exit the program mode as follows:
To exit program mode, turn ignition off, or press and release valet switch.