* These special variables indicated on the next page function in this manner.
* Ideal Ratio- The largest number that can be written into the Ideal Ratio without an
overflow is 640. Variable at address 0426h is 3 bytes, at 0614h is 4 bytes.
* Job Total A (SD2)- This variable will show twice the amount read from the Job A
display. This is because the number is actually a raw count from the freq. input. The
number read will match the totals seen in the Status Display 2 screen.
* Job Total B (SD2)- Same as above.
* Grand Total A- This variable will not be stored into the backup memory until the Job
Volume A has been reset. Therefore the location will read zero until the count is stored
away with the Reset Job A.
* Grand Total B- Same as above.
* Gate Time-This variable is a converted number because the keypad entry is made in
seconds and a constant must be applied for computations. Therefore after reading the
Gate Time the number read must be converted to decimal then divided by 5388 for an
answer in seconds.