The EMO 500 will flash "Direct Selection, Meter A or B" then the display will read
"F2=A, F3=B, F4=A&B". This is where the user can choose the input the selected Flow
Meter and Engineering Unit will be set. The display will the read "More Selections?,
F2=Yes, F3=No". If both Flow Meters are programmed select F3, if not F2 will start the
Meters/Units Program section again.
NOTE: The Engineering Units for A and B should be the same.
NOTE: The (KFR) and (KFT) values in the Meters/Units Programming are only
approximations because the K-factors of the above flow meters are only
approximations. The user should calculate the (KFR) and (KFT) using the
calibrated K-factor whenever possible. This will be covered in the Global
Programming section.