Philips F-2200 Series Automobile Parts User Manual


 
F-2200 Series Vortex Flow Meter Installation and Operation Guide • Revised 12/08
7
SECTION 1.0: INTRODUCTION
We, at ONICON INCORPORATED, would like to thank you for purchasing our F-2200 Series Vortex Flow
Meter. As our valued customer, our commitment to you is to provide fast reliable service and assistance,
while continuing to offer you new products to meet your growing  ow measurement needs.
1.1 PURPOSE OF THIS GUIDE
The purpose of this guide is to provide installation and commissioning procedures and basic
operating and servicing instructions for ONICON F-2200 Series Vortex Flow Meters.
1.2 PRINCIPAL OF OPERATION
ONICON F-2000 series vortex  ow meters utilize Karman’s vortex street principal to detect changes
in velocity in the medium  owing around the titanium shedder bar and through the meter body. A
volumetric ow rate is then derived by utilizing the known cross-sectional area of the meter body
and the average velocity of the medium. When provided with optional temperature and/or pressure
compensation the F-2000 series  ow meters are capable of calculating the required density
corrections necessary to provide direct mass  ow measurement of liquids, steam or gases.
1.3 FEATURES AND SPECIFICATIONS
CONSTRUCTION
Meter body:
Casting: 316 stainless steel for diameters up to 4”
304 stainless steel for 6” and 8” diameters
Shedder bar: Unalloyed titanium
Shedder bar seal: Ni plated Inconnel
Damper pin o-ring:
Viton for, non-steam, -4° to 356° F
Kalrez 4079 for, non-steam, -4° to 428° F
Paro uor for steam, -4° to 464° F
Electronics enclosure:
Enclosure material: Die-cast aluminum
Enclosure viewing window: Tempered glass,
UV blocking
CALIBRATION
Each meter undergoes a 5 point velocity calibration
from 0-250 ft/sec
PROGRAMMING
Each meter is programmed at the factory based on application speci c data provided by the
customer. Field re-programmable via keypad, with coded access for security.
!
WARNING
Only quali ed service personnel should attempt to install or service this equipment. Serious injury
may result from the improper installation or use of this equipment.