Navman G-PILOT 3100 GPS Receiver User Manual


 
G-PILOT 3100 Installation Manual
NAVMAN
14
Installing a electric drive motor with clutch relay
In the VESSEL menu (See G-PILOT 3100
Operation Manual), set DRVE TYPE to MTR.
Installing a continuous running pump and solenoid valves.
In the VESSEL menu (See G-PILOT 3100
Operation Manual), set DRVE TYPE to SPL -.
Fit strain relief
Wiring polarity
does not matter.
Motor
Main unit
Clutch
coil
1N4002 diode or equiva-
lent. Fit close to relay coil
Connector
cover
1N4002 diode or equivalent
Fit close to relay coil
1 2 3 4 5 6 7 8
Relay coil
Main unit
1N4002 diode or equivalent
Fit close to relay coil
Connector
cover
1 2 3 4 5 6 7 8
Relay contacts
Relay coil
Starboard
Port
Motor
Fit strain relief
Heavy duty power (see section 3-4-1)
Heavy duty power (see section 3-4-1)
Wiring polarity
does not matter.
Note: Motor is not
required for engine
PTO systems.
Relay contacts
Note: Relay is required if the
clutch circuit is greater than 300 mA.
Note: Relay is required
if the clutch circuit is
greater than 300 mA.