3. Highlight
FUEL MANAGEMENT and press ENT. Select TANK LOCATION and
press
ENT.
4. Use to select the location (Port, Center or Starboard) of the en-
gine interface you want to calibrate and press
ENT.
5. Highlight
FILL TANK and press ENT. The following confirmation mes-
sage will appear: Are you sure you wish to Fill Tank?
6. Select
YES and press ENTER. The following confirmation message will
appear: Do you wish to re-calibrate the device?
7. Highlight
NO and press ENT. Take your vessel out on the water and
burn at least five gallons of fuel. Be sure you run only ONE engine
— the engine connected to your engine interface.
9. Fill up your tank again, noting how much fuel you added to the tank.
Compare that number to the Fuel Used figure displayed on the page
you customized. If the amount of fuel you added to the tank and the
fuel used figure are off by more than 3 percent, we recommend the en-
gine interface be calibrated.
NOTE:
You must use the gauge's Fill Tank command when filling your fuel
tank to keep the engine interface updated with correct information
on the amount of fuel in the tank.
To calibrate a Suzuki Engine Interface:
10. If calibration is necessary, press MENU|MENU, select NMEA 2000 and
press
ENT.
11. Highlight
FUEL MANAGEMENT and press ENT.
12. Select
TANK LOCATION and press ENT to choose the location of the tank
connected to the selected engine interface. Press
ENT.
13. Highlight
FILL TANK and press ENT. The following message will ap-
pear: Are you sure you wish to Fill Tank? Select
YES and press ENT.
14. The following message will appear: Do you wish to re-calibrate the
device? Select
YES and press ENT.
15. Repeat these steps for each engine interface you want to calibrate.
Engine Trim Calibration
Engine Trim is calibrated through the Suzuki Engine Interface Device
Configuration menu.
1. Press
MENU|MENU, select NMEA 2000 and press ENT.
2. Choose
BUS SETUP and press ENTER. Select the Suzuki Engine Inter-
face connected to the desired engine and press
ENT.
3. Highlight
CALIBRATE TRIM and press ENT. The Device Calibration win-
dow will appear with a list of Calibration Instructions.
4. Highlight
START CALIBRATION and press ENT. The following message
will appear: Please fully raise the Engine Trim.