Honeywell N56XX Automobile Parts User Manual


 
3 - 16
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner’s trigger.
If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if turned on)
for each read. The scanner attempts to find and decode new symbols as long as the trigger is pulled. When this programming
selection is turned Off, the scanner will only read the symbol closest to the aiming beam. Default = Off.
No Read
With No Read turned On, the scan engine notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data
Window (see page 9-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear.
Default = Off.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data
Formatting beginning on page 5-1). The hex code for the No Read symbol is 9C.
Video Reverse
Video Reverse is used to allow the scan engine to read bar codes that are inverted. The Video Reverse Off bar code below is
an example of this type of bar code. Scan Video Reverse Only to read only inverted bar codes. Scan Video Reverse and
Standard Bar Codes to read both types of codes.
Note: After scanning Video Reverse Only, menu bar codes cannot be read. You must scan Video Reverse Off or Video
Reverse and Standard Bar Codes in order to read menu bar codes.
Note: Images downloaded from the unit are not reversed. This is a setting for decoding only.
*Off
On
* Off
On
* Off
Video Reverse Only