Honeywell N56XX Automobile Parts User Manual


 
3 - 15
FF termination string for second code
69 code identifier for Code 93
0012 C - Code 93 sample length (11) plus CR suffix (1) = 12
43 start character match for Code 93, 43h = “C”
FF termination string for third code
Output Sequence Editor
Partial Sequence
If an output sequence operation is terminated before all your output sequence criteria are met, the bar code data acquired
to that point is a “partial sequence.”
Scan Discard Partial Sequence to discard partial sequences when the output sequence operation is terminated before
completion. Scan Transmit Partial Sequence to transmit partial sequences. (Any fields in the sequence where no data
match occurred will be skipped in the output.)
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited sequence or the scan engine will not
transmit the output data to the host device. When it’s On/Not Required, the scan engine will attempt to get the output data
to conform to an edited sequence but, if it cannot, the scan engine transmits all output data to the host device as is.
When the output sequence is Off, the bar code data is output to the host as the scan engine decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Enter Sequence
Default Sequence
Transmit Partial Sequence
* Discard Partial Sequence
Required
On/Not Required