Honeywell N56XX Automobile Parts User Manual


 
3 - 12
Preferred Symbology
The scan engine can be programmed to specify one symbology as a higher priority over other symbologies in situations where
both bar code symbologies appear on the same label, but the lower priority symbology cannot be disabled.
For example, you may be using the scanner in a retail setting to read U.P.C. symbols, but have occasional need to read a code
on a drivers license. Since some licenses have a Code 39 symbol as well as the PDF417 symbol, you can use Preferred Sym-
bology to specify that the PDF417 symbol be read instead of the Code 39.
Preferred Symbology classifies each symbology as high priority, low priority, or as an unspecified type. When a low priority
symbology is presented, the scanner ignores it for a set period of time (see Preferred Symbology Time-out on page 3-13) while
it searches for the high priority symbology. If a high priority symbology is located during this period, then that data is read imme-
diately.
If the time-out period expires before a high priority symbology is read, the scanner will read any bar code in its view (low priority
or unspecified). If there is no bar code in the scanner’s view after the time-out period expires, then no data is reported.
Note: A low priority symbol must be centered on the aiming pattern to be read.
Scan a bar code below to enable or disable Preferred Symbology. Default = Preferred Symbology Off.
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Charts on
page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit
hex value from the Programming Chart (inside back cover). Scan Save to save your selection. Default = None
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology bar code below. On the Symbology Charts on page
A-1, find the symbology you want to set as low priority. Locate the Hex value for that symbology and scan the 2 digit hex
value from the Programming Chart (inside back cover).
If you want to set additional low priority symbologies, scan FF, then scan the 2 digit hex value from the Programming Chart
for the next symbology. You can program up to 5 low priority symbologies. Scan Save to save your selection. Default =
None.
Preferred Symbology On
* Preferred Symbology Off
High Priority Symbology
Low Priority Symbology