Home Automation SIA CP-01 Automobile Alarm User Manual


 
31
To set up your thermostat for use with the energy saver, set it in the appropriate mode and set the temperature to your preference.
NOTE: Your heating and cooling system will always be off if you set your thermostat to Off mode. The PESM cannot turn it
back on. The PESM cannot make your system cool below the thermostat's cool setting, or heat above the thermostat's heat
setting.
Control actions for temperature sensors:
Set low setpoint
Set high setpoint
To enter the temperature menu, from the top-level display or from the main menu, press the 5 (TEMP) key on the console keypad.
You will be prompted with the first named temperature zone (i.e. Upstairs). The temperature zone can be specified by entering
the temperature zone number followed by the ' # ' key, or by pressing the arrow keys to scroll through the list of temperature
zones. Press the ' # ' key when the desired temperature zone is shown.
TEMPERATURE ZONE:
ENTER TEMPERATURE ZONE
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown.
For Programmable Energy Saver Modules:
Upstairs
0=OFF 1=ON 2=HEAT
Upstairs
3=COOL 4=TIME #=STAT
For temperature sensors:
Upstairs
2=LOW 3=HIGH #=STAT
To set a temperature setpoint, press 2 (HEAT) or 3 (COOL).
For Celsius temperatures, press the ' # ' key prior to entering the temperature to make the number negative. The Celsius
temperature may also be specified in 0.5 degree steps if three numeric digits are entered. The third digit adds a .5 to the first two
digits if it is any- thing other than zero. Enter a leading zero if necessary.
In additions to setpoint changes, an energy saver may be turned On or Off. It may also be turned On or Off for a specific
duration.
To turn the energy saver Off, select 0 (OFF). To turn the energy saver On, select 1 (ON). To turn the energy saver On or Off for
a specific duration, select 9 (TIME) prior to selecting On or Off. Enter the time as described under Control - Unit Commands.
Downstairs
0=OFF 1=ON 2=HEAT
Downstairs
3=COOL 9=TIME #=STAT
ENTER TIME
MINUTES (1-99) #=H/M/S
Downstairs FOR 15M
0=OFF 1=ON
The current status of a temperature zone may be displayed by selecting ' # ' (STAT) key from the main temperature menu. The
status display differs depending on the temperature zone type.
When you are finished, press the ' * ' key twice to return to the top-level display.