Fire Alarm Activated
When the fire alarm is activated by the smoke/fire detector(s), the alarm responds exactly as described under Burglar Alarm
Activated, except:
The console display reads, "FIRE ALARM! ZONE NAME TRIPPED".
The sounder will activate in a 3 pulse temporal pattern to distinguish the fire alarm from the burglar alarm.
The fire alarm takes priority over the burglar alarm, however, if a gas alarm is already active, it will not override the gas alarm.
NOTES:
¾ If multiple alarm types occur, such as both Fire and Police, the display will alternate between the alarm types.
¾ To reset smoke detectors, arm the system. When armed, the controller will cycle power to reset smoke detectors.
Gas Alarm Activated
When the gas alarm is activated, the alarm responds exactly as described under Burglar Alarm Activated, except:
The console display reads, "GAS ALARM! ZONE NAME TRIPPED".
The sounder will pulse on - off - on, then an extended off period to distinguish it from the burglar or fire alarm.
The gas alarm takes priority over the burglar alarm, however, if a fire alarm is already active, it will not override the fire alarm.
NOTE:
¾ To reset gas detectors, arm the system. When armed, the controller will cycle power to reset gas detectors.
Emergency Keys
Emergency alarm conditions can be activated through the console. These conditions (Fire, Police, and Auxiliary) are initiated
with the simultaneous depression of two keys for approximately 1 second.
AUX
POL
FIRE
OMNI
NOTE: The Emergency keys are always armed. The Fire and Auxiliary emergency alarms are silenced by pressing the ' * ' key.
To cancel a Police emergency alarm you must press the Off key and enter your code.