Home Automation SIA CP-01 Automobile Alarm User Manual


 
12
Police Emergency
When the 1 key and the 3 key is pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exactly
the same as described for Burglar Alarm Activated except:
The console display indicates: "BURGLARY! - POLICE EMERG TRIPPED".
Fire Emergency
When the 4 key and the 6 key is pressed simultaneously, the Fire Emergency alarm is activated. This alarm operates exactly the
same as described for Police Emergency Button except:
The sounder activates in a 3 pulse temporal pattern distinguish the fire alarm from the burglar alarm.
The console display will read: "FIRE ALM - FIRE EMERG TRIPPED".
The Fire Emergency alarm can be turned off at any time by pressing the ' * ' key.
Auxiliary Emergency
When the 7 key and the 9 key is pressed simultaneously, the Auxiliary Emergency alarm is activated.
The console beeper comes on - display indicates:
"AUX ALARM! AUX EMG BTN TRIPPED".
¾ The console beeper continues to sound until the alarm is disarmed.
Duress Code Entered or Duress Alarm Activated
(See Duress Code for a description of when to use)
In the event that you enter your duress code or a Duress zone is tripped, the system performs a silent dial out as follows:
No alarms, lights or console beepers are activated. The system does not display the duress alarm.
The system waits the Dial Out Delay, and then begins to dial out.
Alarm Reset
The alarm system will reset itself and turn off the sirens after the system has been in alarm for the configured Alarm Reset time
window between 6-30 minutes. When the alarm system resets, any zone that is ready is reactivated, so the alarm system will be
activated again if the zone is tripped. If a zone remains not ready (i.e. a door has been left open) it will be automatically
bypassed when the alarm resets.
Alarm Cancel
At any time, you can disarm and silence an alarm by pressing the Off key and entering your code. If the alarm is disarmed after
the Dial Out Delay but within the Alarm Reset window, the communicator will send the alarm code followed by a code indicating
that the user has canceled the alarm and the console will display " *** ALARM CANCEL *** ".
If an alarm is disarmed before the Dial Out Delay has expired, the system will not report anything to the central station and the
console will display " *** ALARM ABORTED *** ".
If an alarm is canceled during a Voice Dial Out, the system hangs up immediately.