Eclipse Combustion EGA4 Automobile User Manual


 
Instruction Manual MM850481 ed.01
Pressing the [W] and [X] keys, it is possible to zoom-in and zoom-out increasing or decreasing the number of displayed
parameters.
O
2
20.9%
CO
2
0.0%
CO 1
ppm
R
e
f
O
2
GRAPHIC
O2
20
.
9%
:
CO
2000
p
Ta 20.2C : Eff 0.99
Tf 400.3C : NO2 100p
η
95.7% :
CO2 10.2p :
NOx 500p :
R
e
f
O
2
GRAPHIC
Pressing the [S] and [T] you can change page for others parameters.
Pressing the [REF. O
2
] key the measured parameters will be referred to the programmed oxygen value. When selected
this mode, the symbol “O
2
” will be displayed on the status bar.
O
2
20.9%
CO
2
0.0%
CO 1
ppm
R
e
f
O
2
GRAPHIC
If the graphical option (Table E=4 on ordering code) is installed, the instrument can display the measured values as bar-
graph. Press the [GRAPHIC] (F2) key to change mode.
O2
CO
η
R
e
f
.
O
2
NUMERIC
Using GasConfig Software, you can program the graph page: Assign up to 6 different parameter, range and increment
direction. See chapter 9 for software instructions.
Press the [NUMERIC] (F2) key to return to the normal display mode.
7.3 Pressure/Draught measurement
If the internal pressure sensor is installed (Table E=2 on ordering code), you can execute the pressure/draft
measurements using or the standard probe or the special probe.
Standard probe (TG models):
The standard probe has a single gas collector for gas sampling. Usually you have the hose terminal connected to the
instrument gas inlet; when you have to do the draft measurements you have to move the connector to pressure inlet (P
IN) connector.
22