16
multiple event total recall
This will report the last eight system triggers.
1. Press and hold of the PlainView 2 Valet switch.
2. While still holding , arm and disarm the system, then
release the button.
3. The LED will start to blink to indicate the most recent trigger
and proceed down to the eighth trigger. If fewer than eight
triggers are stored in memory, the LED will blink continuous-
ly until the system is armed/disarmed using the transmitter
or the ignition is turned on. For more information, please
refer to the Table of Zones section of this guide.
false alarm control technology (FACT II)
Your system offers FACT
II
, a feature that prevents annoying
repetitive trigger sequences due to a faulty sensor or environmental
conditions such as thunder, jackhammers, airport noise, etc.
Here’s how it works: The alarm triggers three times. If the same sensor is
triggering the alarm and the first and the third triggers are within 60 min-
utes of each other, FACT
II
will interpret this pattern of triggers as false
alarms. After the third trigger, FACT
II ignores, or bypasses, that sensor
(along with any other sensors sharing the same zone) for 60 minutes.
If the bypassed sensor tries to trigger the system while it is being
bypassed, the 60-minute bypass period will start over. This ensures that
a sensor that continually triggers will remain bypassed.