Vector V08 ENT M75 Automobile Parts User Manual


 
INSTALLATION DIRECTIVEMAY 2006
35
V08 ENT M75
-
M11
-
M12
Clogged air filter sensor
Vacuum switch, providing the signal for the clogged air filter
alarm indicator.
Operating voltage: from 6 to 24 V
Condition at ambient pressure normally open
Closing vacuum:
-52 mbar
Operating temperature: -20 / +80 °C
Maximum current 0.1 A (not inductive)
Electrical poles isolated
Clogged oil filter sensor
Differential pressure switch, providing the signal for the
related indicator when pressure difference between inlet /
outlet oil filter is more then a limit value.
Operating voltage: from 6 to 24 V
Condition at ambient pressure normally open
Closing pressure: 2.4 ± 0.3 bar
Opening pressure: 1.8 ± 0.3 bar
Maximum current 3 A (not inductive)
Electrical poles isolated
Figure 40
Figure 41
Clogged fuel filter sensor
Figure 42
Pressure switch, providing the signal for the related indicator,
when the pressure at the fuel filter inlet is too high.
Operating voltage: from 6 to 24 V
Condition at ambient pressure normally closed
Opening pressure: 1.5 ± 0.1 bar
Maximum current 0.1 A (not inductive)
Electrical poles isolated
Exhaust gas temperature sensor
NiCr-Ni thermocouple sensor with insulated poles, pro-
viding the signal for the analog indication of exhaust gas
temperature.
Temperature Voltage
°C mV
100 4.10
200 8.13
300 12.21
400 16.40
500 20.65
600 24.91
700 29.14
800 33.30
900 37.36
Figure 43
04_029_C
04_030_C
04_260_N
04_238_N