Sears 580.32601 Automobile Parts User Manual


 
SERVICEAIR CLEANER
Clean and re-oil Air Cleaner foam pre-cleanerat 3 month intervals or every 25 operating hours,
whichever comes first. Service more often if operating under dirty or dusty conditions. Service
foam pre-cleaner as follows:
1oRemovecover nut and cover.
2. Removefoam pre-cleaner by sliding it up
and off the paper cartridge.
3oA-Wash foam pre-cleaner in liquid
detergent and water,
B-Squeezepre-cleanerdry.
C-Oil pre_cteaner with one ounce clean
engine oil,
D-Squeezeto distribute oi!o
4, Assemble pre-cleaner to paper cartridge,
5o Install cover and cover nut° Turn cover nut
down tight°
t
FOAM _ COVER
PRE-__
HEX NUT
COVER PLATE
PAPER CARTRIDGE "_
Once yearly or every 100 hours of operation (whichever comes first), remove hex nut, cover plate,
and paper cartridge. Clean paper cartridge by tapping gently on a flat surfacer If extremely dirty,
replace cartridge or wash cartridge in liquid detergent and water_ Rinse cartridge until water re-
mains clear, AIR DRY CARTRIDGE THOROUGHLY BEFORE USING.
INSPECT 30 AMP FUSE
The alternator is equipped with a battery charging circuit° This circuit provides an automatic
"trickle" charge of 0 - 8 amps to the unit battery whenever the engine is running. The circuit is
protected by a 30 amp fuse. Inspect the fuse every 25 hours of operation, as follows:
1. Push in on Fuse Cap and turn
counterclockwise to remove° Remove Fuse
Cap and 30 Amp Fuse.
2. Inspect fuse element. If the element is
melted open, replace fuse. Use only an iden-
tical 30 amp replacement fuse.
3. To install Fuse, insert metal end of fuse in-
to Fuse Cap. Install Fuse and Fuse Cap into
Fuse Holder and rotate Cap clockwise while
pushing in on Fuse Cap°
Ho{der
Fuse Element Good
Reinstall Euse (_
Fuse Cap