Technical Data (cont.)
OUTPUTS
Relay:
Contact load 28VDC @ 1A or 120VAC @ 0.5A
Contact protection Must be externally connected.
Required for inductive loads.
RC-element for AC loads. Diode (1N4007) for
DC load.
Terminals E1 - 6 & I1 - 6. Refer to electrical wiring
diagram.
Available Internal Power Supply +24VDC
Overload Protection 2.0A Max current (protected by Fuse 1)
Maximum Load for all Output Voltages COMBINED is 12 watts!
Transistor:
Output: Transistor Output Imax = 100mA for error LEDs
Overload protection Time-limited protection available
Terminals B5 through 9
Inputs:
Signal Type: All inputs must be from potential free contacts.
Terminals: A2 & 7, C4, 7, & 9, D2, F2