Linear LRA Automobile Electronics User Manual


 
LRA Linear Residential Actuator Installation Guide - 17 - 228158 Revision X13 2-3-2009
Loop Layout Illustration
2"
3/8"
4 FT.
MINIMUM
USE RELIEF CUTS
AT CORNERS
TWIST WIRE FROM END OF
LOOPS BACK TO OPERATOR
AT LEAST SIX TIMES PER
FOOT
2" MAX.
LOOP
SEALANT
MULTIPLE TURNS
REFER TO LOOP
INSTALLATION NOTES
FOR DETAILS
OPEN
GATE
PARTIALLY
SHOWN
NOTE: POSITION SHADOW LOOP APPROXIMATELY HALF WAY
BETWEEN ENTRY AND EXIT REVERSING LOOPS. THE DISTANCE
BETWEEN THE SHADOW LOOP AND EXIT/REVERSING LOOPS
SHOULD NEVER EXCEED THE LENGTH OF THE SHORTEST
VEHICLE TYPE WHICH IS EXPECTED TO USE THIS GATE.
WALL PARTIALLY
SHOWN FOR CLARITY
SEPARATE PEDESTRIAN
GATE REQUIRED
7 FT. MINIMUM DISTANCE
AWAY FROM GATE
6 FT.
NOTE: POSITION SHADOW LOOP WITH
A MINIMUM OF 4' CLEARANCE FROM
GATE'S FULLY OPEN OR CLOSED POSITION