Linear LRA Automobile Electronics User Manual


 
LRA Linear Residential Actuator Installation Guide - 14 - 228158 Revision X13 2-3-2009
Advanced Controller Programming (Cont.)
Auxiliary Relay Mode
The Auxiliary Relay has normally open and normally closed contacts.
The factory setting disables the Auxiliary Relay. The relay can be set for:
Maglock:• The relay will energize during any pending or actual gate
motion (open only), to deactivate a magnetic or solenoid gate lock.
Ticket Dispenser:• The relay will energize while the gate is moving
in the open direction and at the full open limit, or in an entrapment
condition.
Strobe:• The relay will energize during any pending or actual gate
motion (either open or close), to activate a warning strobe light.
Alarm:• The relay will energize if the gate is manually forced open
from the full closed position.
Reverse Delay Time
The factory default sets the Reverse Delay to 1 second. The operator
will wait the length of the delay before reversing direction. This feature
will not change the reversal time when the operator is responding to an
entrapment condition from an obstruction input or inherent entrapment
protection sensor. The Reverse Delay can be set from 1 to 9 seconds.
Heaver gates require a longer delay to allow time for the gate to stop.
Low Power Mode
This function is only used with DC battery backup. The factory default
disables the Low Power Mode. When Low Power Mode is enabled, and AC
power fails, the controller will assume Low Power Mode after 60 seconds
of gate inactivity. Low power mode turns off all accessory power and
indicators. Only inputs from the radio receiver, reverse loop, or restoring
AC power will wake the Controller from Low Power Mode. Programming
Mode can still be accessed while the Controller is in Low Power Mode.
Power Failure Mode
This function is only used with DC battery backup. The factory default
is set for Fail Safe, alternately the Controller can be set for Fail Secure,
Open Immediate, or Close Immediate.
Fail Safe:• If the AC power fails and the battery voltage drops below
approximately 22 Volts, 5 seconds later the operator will cycle open
if not already open. When AC power is restored, or the battery gets
charged by solar panels, the operator will resume normal operation
and auto-close if programmed to do so.
Fail Secure:• If the AC power fails and the battery voltage drops
below approximately 22 Volts, 5 seconds later the operator will
cycle closed if not already closed. When AC power is restored, or
the battery gets charged by solar panels, the operator will resume
normal operation.
NOTE: Fail Safe and Fail Secure are disabled if Stagger Mode is
enabled.
Open Immediate:• If the AC power fails, the operator will cycle
open if not already open and cease operation. When AC power is
restored, the operator will resume normal operation and auto-close
if programmed to do so.
Close Immediate:• If the AC power fails, the operator will cycle
closed if not already closed and cease operation. When AC power is
restored, the operator will resume normal operation.
FUNCTION
AUXILIARY RELAY USED FOR
MAGLOCK CONTROL
AUXILIARY RELAY DISABLED
AUXILIARY RELAY USED FOR
TICKET DISPENSER CONTROL
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUXILIARY
RELAY MODE
"AR"
AUXILIARY RELAY USED FOR
WARNING STROBE LIGHT
AUXILIARY RELAY USED FOR
CONNECTION TO ALARM DEVICE
FUNCTION
LOW POWER MODE DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
LOW POWER
MODE
"LP"
LOW POWER MODE ENABLED
DC MODELS
ONLY
FUNCTION
SET TO FAIL SAFE MODE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
POWER
FAILURE MODE
"FS"
SET TO FAIL SECURE MODE
DC MODELS
ONLY
SET TO OPEN IMMEDIATE MODE
SET TO CLOSE
IMMEDIATE MODE
FUNCTION
SET TIMER VALUE
1 TO 9 SECONDS
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
REVERSE
DELAY TIME
"RD"