Honeywell KA 54 Radar Detector User Manual


 
N
KRA 405B RADAR ALTIMETER INSTALLATION MANUAL
Page 1-13
006-10536-0010 Rev. 10 Oct/2005
The CM 2000 allows the KRA 405B to operate with custom altitude trip
points (rather than the factory preset values) and allows for an
offset to the zero foot readout. Refer to section 2.4 CONFIGURABLE
PARAMETERS to determine if the module is required for a particular
installation.
B. KPA 900 CONFIGURATION MODULE PROGRAMMER KIT
The KPA 900 Configuration Module Programmer Kit is required to
program the CM 2000 Configuration Module. Prior to the installation
of the CM 2000, it must be programmed to store the custom
specifications. Refer to the KPA 900 Programmer Operator’s Guide
for complete instructions.
The KPA 900 is not part of the installation but rather a piece of
equipment retained by the installer. If the installer does not have
access to a KPA 900 with current software and the CM 2000 is
required, order P/N 050-03311-0002 which contains the items listed
below.
XX=Highest Revision
NOTE: For CM 2000 Configuration Modules used in ART 2000 Weather
Radar and KRA 405B Radar Altimeter Installations and CM
2000 configuration modules that have never been pro-
grammed or may have a default program for a different
unit, a “write to” initialization must be performed be-
fore writing the parameters required for the installation
into the CM 2000 configuration module. From the File menu,
load the default RDR 2000 or KRA 405B file into memory
and perform a “write to” from the hardware menu. This will
ensure that a correct default program, without errors, is
present. The default program can then be modified from
View in the memory menu. Refer to sections 1.4.2.1,
1.4.2.2, and 1.4.2.3 of the KPA 900 operators guide (006-
05392-00XX).
PART NUMBER DESCRIPTION UM QTY VENDOR PART NUMBER
006-05392-00XX Operator’s Guide EA 1 Honeywell
050-03281-0000 KPA 900 Programmer EA 1 Honeywell
222-00366-0XXX Software Disc EA 1 Honeywell