Furuno 1944C-BB Radar Detector User Manual


 
3. PLOTTER OPERATION
3-53
3.11.9 Alarm information
When an alarm setting has been violated, the buzzer sounds and the speaker icon appears
and is red. Press the CLEAR key to silence the alarm. You can see which alarm has been
violated on the ALARM menu. In the example below the arrival alarm has been violated.
1. Press the ALARM key. The name of the offending alarm appears in the alarm
information window.
ALARM1
Alarminformation
window
Speaker icon
XXX = Destination waypoint name
AUDIOALARM INTERNALBUZZ
ARRIVALALARM ON0.010nm
ANCHORWATCHALARM OFF0.010nm
PROXIMITYALARM OFF
XTEALARM OFF0.050nm
SPEEDALARM OFF
TRIPALARM OFF0000.0nm
ALARMINFORMATION
ARRIVED
ATWAYPOINTXXX!
NEXT
PAGE
D
RETURNE
EDITA
CLEAR
ALARM
C
Plotter alarm menu, page 1
2. Press the C: CLEAR ALARM soft key to acknowledge the alarm (and silence the buzzer
if it was not done with the CLEAR key). The color of the speaker icon changes from red
to background color. The icon remains on the screen until the cause of the alarm is
eliminated or the alarm is disabled. If more than one alarm has been violated the
message CONTINUE appears at the bottom of the alarm information window. In this
case, press the B: NEXT INFO soft key to see which other alarms have been violated.
3. Press the ALARM key to finish.
Note: The alarm icon is red when an alarm setting is violated, and changes to background
color when the CLEAR key or C: CLEAR ALARM soft key is pressed. The color does not
change regardless of how many other alarms are violated.