24 © 2000 Directed Electronics, Inc. Vista, CA
4 DOOR TRIGGER INSTANT/DELAYED: In the instant (default) setting, if a door is opened while the security
system is armed the system will trigger immediately. In the delayed setting there is a 15-second delay before the
doors will trigger the system. This allows the user 15 seconds to disarm the system after a door is opened without
the factory transmitter.
5 DOOR TRIGGER ERROR CHIRP ON/OFF: With the door trigger error chirp programmed off, the system will not
report an invalid zone on arming when the door trigger wire is active. This eliminates the extra chirps that occur
when interfacing with vehicles that have exceptionally long dome light delay circuits.
6 SENSOR SHUNT ZONES 2 and 4/ALL ZONES: In the default setting all sensors, with the exception of the door
zone, will be bypassed when a trigger is grounded three seconds after the trunk is opened (i.e. when there is a
(+) pulse on the WHITE/BLUE wire). If this feature is programmed to the all zones setting, all zones, including
the doors, will be bypassed when the trunk is opened with the factory transmitter.
7 PANIC/AUXILIARY OUTPUT: When this feature is programmed for Panic Mode (default setting), pressing the
lock button on the factory transmitter twice within three seconds will trigger Panic Mode. In this setting, the
H1/12 RED/WHITE wire becomes a delayed accessory output. This wire will provide (-) ground when the ignition
is turned off and will continue to output (-) ground until a door is opened. This can be used to energize the
accessory circuit in the vehicle to keep the radio and other accessories on after the ignition is turned off. If pro-
grammed to the auxiliary output setting, pressing the lock button twice within three seconds will send a (-) pulse
on the RED/WHITE auxiliary output wire.
8 NO FUNCTION
9 VALET PULSE COUNT 1-5 PULSES: The system can be programmed to count the number of presses of the Valet
switch before disarming the security system. The factory default setting is one pulse. The unit can be set for
2-5 pulses using the unlock button on the transmitter to select the setting.
GHOST SWITCH OPTION: For added security, the GRAY wire on the two-pin Valet/program switch can
be connected to any switch in the vehicle that provides a positive (+) momentary pulse. This switch
must be active while the ignition is on.