Directed Electronics 417 Automobile Alarm User Manual


 
22 © 2000 Directed Electronics, Inc. Vista, CA
system features learn routine
The System Features Learn Routine dictates how the unit operates. It is possible to access and change any of the
feature settings using the Valet/program switch.
To enter the System Features Learn Routine:
1. Open a door.
2. Key. Turn the ignition on, and then off. (The H1/9 YELLOW wire must be connected.)
3. Select a feature: Press and release the Valet/program switch the number of times corre-
sponding to the feature you wish to program. (See the following table of features.) For
example, to access the third feature, press and release three times. Then press the button
once more and HOLD it. The siren will chirp the number of times corresponding to the
feature you have accessed.
4. Program the feature: While HOLDING the Valet/program switch, you can toggle the feature
on and off using the remote transmitter. Pressing the button that locks the door will select
the one-chirp (default) setting. Pressing the unlock button will select the two-chirp setting.
NOTE: Feature 9 (Valet pulse count) has five possible settings. Pressing the unlock
button will toggle through all the possible settings.
DEFAULT ONE-CHIRP SETTINGS TWO-CHIRP SETTINGS
FEATURE (PRESS TRANSMITTER LOCK BUTTON (PRESS TRANSMITTER UNLOCK BUTTON
NUMBER OR DOOR LOCK SWITCH) OR DOOR UNLOCK SWITCH)
1 Active Arming Passive Arming
2 Confirmation Chirps ON Confirmation Chirps OFF
3 Siren duration 30 seconds Siren duration 60 seconds
4 Instant door trigger delayed door trigger
5 Door trigger error chirp ON Door trigger error chirp OFF
6 Sensor shunt Zones 2 and 4 Sensor shunt all zones
7 Panic Mode enabled Auxiliary output enabled
8 No function
9 Valet switch input 1 pulse Valet switch input 2-5 pulses
NOTE: Factory defaults are indicated in bold type.