Clifford 6000 Automobile Alarm User Manual


 
FACT—False Alarm Control and Test
The system microprocessor automatically checks for another activated sensor or trigger before sound ing the siren a second time, thus
preventing any further false alarms. If you wish to test FACT, simply,
1. Arm the sys tem with the re mote con trol.
2. Wait 10 seconds after the interior light turns off, then trigger the Piezo Sensor to activate the s iren.
3. Do not disarm the system, let the siren complete its cycle.
4.Trigger the sensor again. The alarm should be silent.
5. Unlock and open a door. The alarm should sound immediately. You may now disarm.
Eight-Event TotalRecall
The system’s nonvolatile memory records the identity of the last eight activated or malfunctioning triggers and sensors.
NOTE: The CliffNet Wizard Pro dis plays the Eight- Event To tal Re call data in a graphi cal for ma t.
1.With the ignition OFF, press and hold the unmarked side of the PlainView 2 Switch.
2. Use the remote control to arm, and then again to disarm, and then release the button.
3. The LED will flash 1–10 times, pause, then flash 1–10 times, etc. Write down the number of flashes in each cycle.
4.Refer to the following chart. The first number you wrote down was the most recently activated trigg er or sensor. The next number
is the second most recent, and so on up to as many as the last eight activations.
Num ber of LED flashes be tween pauses Trig ger/sen sor in di ca tion
1 flash Glass Tampering Sensor
2 flashes Dual-Zone Piezo Sensor
4 flashes Door Trigger
5 flashes Trunk Trigger/Hood Trigger (trunk only, if IntelliStart 4 has been installed)
6 flashes Hood Trigger (only if optional IntelliStart 4 has been installed)
7 flashes
An attempt was made to turn on the
ignition or start the engine while the system was armed
8 flashes More than three consecutive incorrect valet codes were entered
10 flashes System Power Interruption
5. If a sensor is often activated, decrease that sensor’s sensitivity (or reposition the sensor, if ne cessary). If a certain trigger is often
activated, check pin switch operation, verify that the pin switch is not exposed to moisture and ch eck the trigger wire for possible
shorting.
6 In tel liGuard 6000/1298