Autostart CT-5000 Remote Starter User Manual


 
CT-5000 Installation Guide P.7
10
WHITE
(–) Ground
out when
running
This is a 500-mA constant ground output that is active when the vehicle
is running under a remote start. The output becomes active at the same
time as the Ignition, and becomes inactive when the Module shuts
down (i.e.: runtime has expired or the
START/STOP button is pressed,
etc.). The output can be used to activate external relays, bypass kits,
etc.
CAUTION! If multiple relays or modules are connected to the Ground
Out wire, ensure that they are all diode isolated in order to avoid
feedback and damaging the vehicle.
11
GRAY
(–) Negative
Door input
This input should be used in vehicles that use a negative-switching
Dome Light circuit. Connect to a Dome Light wire testing ground with a
Door open.
CAUTION! You can only use a negative or a positive connection. In
other words, only the NEGATIVE DOOR INPUT or the POSITIVE
DOOR INPUT wire is connected. It is essential that the Module be
connected in such a way as to allow each one of the Doors to turn off
Ready Mode: the driver-side Door Pin does not constitute by itself a
sufficient connection.