Magnadyne X9 Remote Starter User Manual


 
26
In this test mode, the installer can save time adjusting the optional sensor sensitivity without using the traditional
arming/disarming procedures to adjust the sensor.
With the ignition switch in the OFF position, turn the
ignition switch On - Off - On - Off - On - Off.
ON
OFF
3X
Before 15 seconds has passed, push and release the
valet switch 6 times holding the button down on the 6th
press. Wait until five (3) chirps/beeps and a long chirp
then release it. You are now in “Shock Sensor” Test
mode.
5X + 1X (Hold)
Shock Sensor Test Mode
Step 1 Step 2
Press the button. 2 chirps will confirm you are now in
Shock Sensor test mode.
1. Walk around the vehicle and slap the body panels with
the palm of your hand
2. A short Chirp indicates a pre-warning level detection
3.
A long Chirp indicates a system trigger level detection
4. Adjust the sensor with a flat blade screwdriver.
Continue to test the sensor until you reach the desired
settings.
Turn On the ignition key to exit the test mode. The horn/siren will chirp 3
long chirps and the parking lights will flash 3 times.
Step 4
Exit Programming
Step 3
Adjust the Shock Sensor
ON